Tailtrack area lighting Gein (replacement of masts, luminaires and cables, design and installation work)

GVB Infra B.V. · Onderhandse procedure · 1 lots · 328627
Type
Works
45316000
Estimated value
Not published
To deadline
Ongoing
Knock-outs
n/a
exclusion grounds
Award basis
Best price-quality ratio
Assess manuallyconfidence low

GVB Infra B.V. wishes to replace the existing area lighting installation on the tailtrack at the Gein passenger station. The assignment includes the removal, transport, storage, and installation of various lighting luminaires, light masts, power cables, cable support systems, fire-resistant seals, and an outdoor enclosure with switching and distribution equipment including back-up power. Additionally, the new installation must be designed, the cables must be connected to the low-voltage distributor, and the old components must be safely dismantled and disposed of. The scope is detailed in the Program of Requirements, Annex 2. The procedure is a negotiated procedure, allowing a limited number of certified suppliers to be approached. The works require precise coordination with the metro and station infrastructure and must comply with safety and fire-resistance requirements. The contracting authority expects an integrated solution that improves lighting quality and reduces maintenance costs.

Works · Onderhandse procedure · National procedure

Contracting authority
Contract type
Works
Onderhandse procedure
Estimated value
Estimate not published
Submission deadline
Ongoing
Scope
National
National procedure
Lots
1
1 lots
Main CPV code
Location
Netherlands
CharacteristicsCPV 45Worksarea lightingtailtrackGVB

01What is being requested

GVB Infra B.V. wishes to replace the existing area lighting installation on the tailtrack at the Gein passenger station. The assignment includes the removal, transport, storage, and installation of various lighting luminaires, light masts, power cables, cable support systems, fire-resistant seals, and an outdoor enclosure with switching and distribution equipment including back-up power. Additionally, the new installation must be designed, the cables must be connected to the low-voltage distributor, and the old components must be safely dismantled and disposed of. The scope is detailed in the Program of Requirements, Annex 2. The procedure is a negotiated procedure, allowing a limited number of certified suppliers to be approached. The works require precise coordination with the metro and station infrastructure and must comply with safety and fire-resistance requirements. The contracting authority expects an integrated solution that improves lighting quality and reduces maintenance costs.

GVB RIB wants to have the existing area lighting installation on the tailtrack at the Gein passenger station replaced. The lighting installation consists of, among other things: • Lighting luminaires on walkways; • Lighting luminaires along and between metro tracks; • Emergency exit luminaires along metro tracks; • Light masts along and between metro tracks; • Power cables along and between metro tracks; • An outdoor enclosure with switching and distribution equipment (incl. back-up power); • Cable support systems in the passenger station; • Fire-resistant seals for cable penetrations

45316000Works
1Tailtrack area lighting Gein (replacement of masts, luminaires and cables, design and installation work)

02Value in context

Estimate not published

The contracting authority did not publish an estimated value — common for a large share of contracts. The EU threshold for werken is € 5,54 M, for reference.

03Likely competitors

#Likely bidderFitWins
1Heijmans Infra B.V.SME9565×
2KWS Infra B.V.SME9492×
3Combinatie Heijmans - SWARCOUnknown9373×
4BAM Infra B.V.SME9377×
5ENGIE Infra & Mobility B.V.SME9369×
6Boskalis Nederland B.V.SME9169×

04Legal themes that may be relevant here

05Frequently asked questions

What is the exact scope of the replacement of the area lighting at Gein station?
The assignment includes the replacement of lighting luminaires on walkways, luminaires along and between metro tracks, emergency exit luminaires, light masts, power cables, cable support systems, fire-resistant seals at cable penetrations, and an outdoor enclosure with switching and distribution equipment including back-up power.
Which works regarding the existing installation are part of the assignment?
In addition to the design and installation of the new installation, the assignment also includes the removal, transport, and disposal of the existing installation components, as well as the transport and storage of parts of the new installation.
What is the expected technical integration of the new lighting installation?
The new installation must be designed such that the cables are connected to the low-voltage distributor in the passenger station. The assignment aims for an integrated solution that improves lighting quality and reduces maintenance costs.

Automatically compiled from the official tender data and documents.