ClosedWorksRestricted
Selection building contractor renovation Willemsparkschool in Amsterdam
Schoolvereniging "Willemspark" · Restricted · 1 lots · 368149
6
6 of 6 core insights found
Measures presence, not accuracy · documents remain authoritative
ScopeAdvicePoints of attentionSuitability requirementsAward criteriaTimeline
Type
Works
45000000
Estimated value
Not published
To deadline
Ongoing
Knock-outs
0
exclusion grounds
Award basis
Best price-quality ratio
4 criteria
Assess manuallyconfidence high
This project concerns the integral renovation and sustainability improvement of the monumental Willemsparkschool in Amsterdam. The selection takes place based on suitability and experience with monumental utility buildings.
Works · Restricted · National procedure
Complete timeline
CharacteristicsCPV 45Works
01What is being requested
The assignment concerns the building and installation technical renovation of the Willemsparkschool, including the reconstruction of the playground and the installation of an ATES source over an area of approximately 1,500 m2.
See guidelines
1building contractor including installation technical works—
02Strategic insight
Strategic insight · AI analysis
During the selection phase, focus heavily on demonstrating renovation experience with monumental buildings. Ensure that the reference projects exactly meet the specified size and functional requirements. Emphasize expertise in developing TO to UO to maximize selection points.
03Points of attention
Important · 4
The tender follows a national non-public procedure.Important
Specific formal requirements for application and signing must be met.Important
References may be a maximum of five years old.Important
The assignment is executed as one lot.Important
04Can I take part?
Financial · 3
General liability insurance with a minimum amount of € 2,500,000.00 per case and € 5,000,000.00 per year.Financial
Taking out Construction-All-Risks (CAR) insurance after award.Financial
Providing a classic bank guarantee.Financial
Technical · 6
Possessing a certified quality management system ISO 9001 : 2015 or equivalent.Technical
Possessing a certified safety management system in accordance with VCA** version 2017/6.0 or equivalent.Technical
Core competency 1: Experience with construction in an inner-city area (utility building with public function, min. 900 m2 GFA).Technical
Core competency 2: Experience with renovating a utility building (min. 900 m2 GFA).Technical
Core competency 3: Experience with renovating a monumental building (min. 500 m2 GFA).Technical
Core competency 4: Experience with coordination of execution works as main contractor (building, electrical, and mechanical, min. 900 m2 GFA).Technical
05Award criteria
Plan proposal10 punten
Preparation and execution planning20 punten
Plan of Approach10 punten
Bid amount60 punten
06Process & timeline
Contracting contractor
Augustus 2025
Work preparation
September 2025 tot December 2025
Realization
Januari 2026 tot September 2026
Delivery
Begin oktober 2026
Commissioning
Maandag na de herfstvakantie 2026
07Value in context
Estimate not published
The contracting authority did not publish an estimated value — common for a large share of contracts. The EU threshold for werken is € 5,54 M, for reference.
08Likely competitors
#Likely bidderFitWins
1Kernbouw B.V.SME9611×
2KWS Infra B.V.SME9592×
3Hegeman Bouw & Infra B.V.SME9531×
4Combinatie Heijmans - SWARCOUnknown9573×
5Dura Vermeer Infra Regionale Projecten BVSME9558×
6BAM Infra B.V.SME9577×
09Tender documents
NIEUW Bijlage 5 formulier referenties selectiecriteriadocxMar 4, 2025 · 112 KB
20250304 Nota van Inlichtingen selectiefasepdfMar 4, 2025 · 63 KB
Bijlage 3 UEApdfFeb 18, 2025 · 2101 KB
Bijlage 4 formulier referenties geschiktheidseisendocxFeb 18, 2025 · 856 KB
Bijlage 6 Model Nota van InlichtingenxlsxFeb 18, 2025 · 11 KB
TN512374 - EF16 Aankondiging van een opdracht - algemene richtlijn, standaardregeling 20250218145700pdfFeb 18, 2025 · 7 KB
20250218 Selectieleidraad aannemersselectie WPSpdfFeb 18, 2025 · 1107 KB
Bijlage 5 formulier referenties selectiecriteriadocxFeb 18, 2025 · 112 KB
10Legal themes that may be relevant here
Advies 63> Meervoudig onderhandse aanbesteding voor het reinigen van wegen, straten en pleinen. Kan bij gunning op laagste prijs de indieniAdvies 48> Europese niet-openbare procedure voor werktuigkundige en elektrotechnische installaties van de nieuwbouw van een multifunctionelAdvies 59> Meervoudig onderhandse aanbestedingsprocedure met betrekking tot een opdracht voor de levering van postdiensten en bezorging. InAdvies 50> Europese niet-openbare procedure met nadere selectie met betrekking tot een overheidsopdracht voor het maken van een ontwerp tenAdvies 53> Europese openbare procedure voor een overheidsopdracht tot het verrichten van diensten bestaande uit (dagelijks en periodiek) sc
11Frequently asked questions
What is the specific core competency tested during selection?
Candidates must have demonstrable experience in developing a Technical Design (TO) into an integral Ready-for-Execution Design (UO) for the disciplines of building construction, structural engineering, and installation technology of a building with a minimum size of 900 m² GFA.
How is the experience in developing a TO to UO assessed?
Experience is weighted based on the type of work: new construction yields 5 points, renovation yields 15 points, and renovation including monumental status yields 20 points.
What requirements apply to the size and nature of the reference projects?
The projects must have a minimum size of 900 m² GFA and completion must have taken place no more than 5 years prior to the deadline for application.
What is the role of the candidate in developing the design?
The candidate must have been responsible for the full development of the drawing work, whereby advisors held a controlling role.
Automatically compiled from the official tender data and documents.
12Estimated value versus the market
p25
€ 1,4 mln
€ 1,4 mln
median
€ 3,6 mln
€ 3,6 mln
p75
€ 9,1 mln
€ 9,1 mln
deze opdracht
Gegunde waarden in CPV 45 · werken n=3159